Input voltage : 100 to 240 VAC / 50-60 Hz
Output voltage : 29 VDC (27.6-30.4 VDC)
Power / current : 2 A nominal
Electrical protection :
– protection against over-current (input / output)
– protection against over-voltage (output)
– protection against short-circuit
– protection against over-load
Consumption in stand-by mode : 0.3~0.4 W
Insulation resistor : 100 Mohms or above at 500 VDC
Protection grade : IP42
Leak current : < 0.75 mA at 230 VAC full load
Protection class : Class II
Operating temperatures : 0° to +40°
Duty cycle : 10% (2 mn operation / 18 mn rest)
Colour : black (RAL 7001)